Laminar Air Flow

1 (2)

Enquire Now

Horizontal laminar air flow

Pureair” Horizontal Laminar airflow manufacturer in Chennai ideal for Microbiological manipulations, work with bio-assays, sterility testing and research work; Vial filling and bunging operations in parenteral units and general dry processing work in semiconductor manufacture and Tissue culture work.

Horizontal Laminar Airflow (unidirectional Airflow) is a confined area moving in a uniform velocity along parallel flow lines. A continuous wash of HEPA/ULPA filtered Air moving horizontally across the work area. The uniform stream of air filtered air moves forward over the work surface from the rear of the work area. The airflow across the work area directly at the user and exhausts into the surrounding area.

Floor Mounted Version suitable when floor space is available.

ContentInformation
ProductPureair” Horizontal laminar Airflow – Standard Version
DimensionsAs per drawings enclosed.
MOCGalvanized Iron with PU coated / Stainless Steel – Satin Finish / Wooden laminated (Except Filters and Motor – Blower Filters).
Pre FilterPureair” Make Pre Filter with Micro Glass Fibre Media of EU – 4 Rating.
Supply HEPA FilterImported Minipleat HEPA Filter efficiency 99.97% Down to 0.3µ H-13 Rating.
Motor Blower AssemblyInduction Motor with Centrifugal Blower Statically and Dynamically balanced with Suitable Rating and Size.
MountingUnique Spring Suspension Systems to take care of Vibration and Noise.
Working TableS.S. 304 with Due Reinforcement for Better Performance and Stability.
Side Panel Accessory No.Clear Glass Side Panels / Clear Acrylic panel / UV Protected Polycarbonate panel
Pressure GaugeDWYER, USA Minihelic Differential Pressure Gauge / Pureair” Inclined manometer.
LightsFluorescent Tube with Milky White Diffuser.
Other Electricals3 Pin Socket, 15 AMP – 1 No. – On / Off Switches with Indicator.
Performance
Air CleanlinessClass ISO – 5 (as per ISO – 14644-1).
Air Flow Rate0.45 ± 0.05mps. or 90 FPM ± 10 FPM
Illumination Of LightMinimum 800 Lux on work table
Noise LevelLess than 67 db on Scale ‘A’ When Ambient sound Level is not Greater than 57 db on Scale ‘A’
Vibration LevelMinimum.

Option at Extra Cost

 1 UV Light & Hour Meter

Vertical laminar air flow

Stand Mounted Version: Vertical Laminar Airflow (unidirectional Airflow) is an confined area moving in a uniform velocity along parallel flow lines. A continuous wash of HEPA/ULPA filtered Air moving downwards across the work area. The uniform stream of air filtered air moves forward over the work surface from the rear of the work area. The airflow across the work area directly at the user and exhaust.

Since Clean Air flows down wards from the above, the straddle configuration facilitates operators to sit on either side of the work area doubling unit utilization and increasing productivity
ContentInformation
ProductPureair” Vertical laminar Airflow – Stand Mounted Version
DimensionsAs per drawings enclosed.
MOCGalvanized Iron with PU coated / Stainless Steel – Satin Finish / Wooden laminated
Supply HEPA FilterImported Minipleat HEPA Filter efficiency 99.97% Down to 0.3µ H-13 Rating.
Motor Blower AssemblyInduction Motor with Centrifugal Blower Statically and Dynamically balanced with Suitable Rating and Size.
MountingUnique Spring Suspension Systems to take care of Vibration and Noise.
Working TableS.S. 304 with Due Reinforcement for Better Performance and Stability.
Side Panel Accessory No.Clear Glass Side Panels/ Clear Acrylic panel/ UV Protected Polycarbonate panel
Pressure GaugeDWYER, USA Magnehelic Differential Pressure Gauge/ Pureair” Inclined manometer.
LightsFluorescent Tube with Milky White Diffuser.
Other Electricals3 Pin Socket, 15 AMP – 1 No. – On / Off Switches with Indicator.
Air CleanlinessClass ISO – 5 (as per ISO – 14644-1).
Air Flow Rate0.45 ± 0.05mps. or 90 FPM ± 10 FPM
Illumination Of Light Minimum 800 Lux on work table
Noise LevelLess than 67 db on Scale ‘A’ When Ambient sound Level is not Greater than 57 db on Scale ‘A’
Vibration LevelMinimum.

Vertical laminar air flow

Pureair” offers international standard IVF Version Vertical Laminar Flow Cabinets that have been designed specifically for polymerase chain reaction applications. Different than conventional dead air boxes, this enclosure features ISO Class 5 (US Federal Standard 209E Class 10) product protection standard within the work zone by vertical laminar airflow. The system is unique, superior and economical alternative to conventional dead-air boxes and passive chambers, which are traditionally used for IVF applications.

The IVF Version Vertical Laminar Flow Cabinets provide a particulate-free work environment and isolates critical steps in the IVF process from contamination present in the ambient environment. The system can be operated effectively as “mini-environments” in clean rooms, and also in laboratory. The system has a positively pressurized interior ensuring that contamination from the ambient environment cannot enter the work zone.
ContentInformation
ProductPureair” Vertical laminar Airflow – IVF Version
ApplicationIn- Vitro Fertilization Application
DimensionsAs per drawings enclosed.
MOC.Galvanized Iron with PU coated / Stainless Steel – Satin Finish / Wooden laminated
Pre FilterPureair” Make Pre Filter with Micro Glass Fiber Media of EU – 4 Rating.
Supply HEPA FilterImported Minipleat HEPA Filter efficiency 99.97% Down to 0.3µ H-13 Rating.
Motor Blower AssemblyInduction Motor with Centrifugal Blower Statically and Dynamically balanced with Suitable Rating and Size.
MountingUnique Spring Suspension Systems to take care of Vibration and Noise.
Working TableS.S. 304 with Stabilized Heating Table with Microscope Arrange ment
Side Panel Accessory No.Clear Glass Side Panels/ Clear Acrylic panel/ UV Protected Polycarbonate panel
Pressure GaugeDWYER, USA Magnehelic Differential Pressure Gauge/ Pureair” Inclined manometer.
LightsFluorescent Tube with Milky White Diffuser.
Other Electricals3 Pin Socket, 15 AMP – 1 No. – On / Off Switches with Indicator.
Other Electricals3 Pin Socket, 15 AMP – 1 No. – On / Off Switches with Indicator.
Air CleanlinessClass ISO – 5 (as per ISO – 14644-1).
Air Flow Rate0.45 ± 0.05mps. or 90 FPM ± 10 FPM
Illumination Of LightMinimum 800 Lux on work table
Noise LevelLess than 67 db on Scale ‘A’ When Ambient sound Level is not Greater than 57 db on Scale ‘A’
VibrationLevel Minimum.

Enquiry Now

GET INSTANT QUOTE


GET INSTANT QUOTE

GET INSTANT QUOTE
Close