1. Biosafety Cabinet – Class II Type A1

Pure Air India, Laboratory Biosafety Cabinet Manufacturer in  India Offers a huge range of Biological Safety Cabinets/Biosafety Cabinets which is used in hospitals, laboratories and clinical research Institutes. We specialize in manufacturing Biosafety Cabinets that are both standard and uniquely designed to meet the demanding requirements specialized research applications. The apparatus is controlled by microprocessors, and all important parameters are digitally displayed. A double door pass through box on the floor-standing and portable cabinet allows access for the passage of materials inside. With the quality of our product we are being the best biological safety cabinet manufacturer in India/ laboratory biosafety cabinet supplier in India.  Buy Biosafety Cabinet at best price in India from us.

“Pureair” Biosafety Cabinet Class II Type A1 is designed for protection of operator, product and environment from pathogenic agents and microorganisms transmitted in respiratory way and also for creation of a bacterial dust free air environment. It has a common plenum from which 30% of air is exhausted, and 70% re-circulated to the work area as the downflow. Type A cabinets exhaust air directly back to the laboratory, and they may contain positive pressure contaminated plenums. When toxic chemicals must be employed as an adjunct to microbiological processes, these cabinets should not be used. Exhaust HEPA filtration only removes airborne aerosols including biohazards, and not chemical fumes.

The Class II Type A1 has the positively-pressurized contaminated plenum bordering the ambient environment, and therefore is less safe than the Class II Type A2 that has a negative pressure surrounding the positively pressurized contaminated plenum. In case there is a leakage on the positive plenum, the leaking aerosol will be pulled by the negative pressure back to the positive plenum, and it will not leak out. Because of the safety issue, the Type A1 design is now considered obsolete. In the A1 cabinet, about 70% of air from the positive plenum is recirculated as downflow, and the remaining All Class II biological safety cabinets type A1 is suitable for work with microbiological agents assigned to biosafety levels 1, 2 and 3.

Working Area – Stainless Steel IS 304 Grade Satin Finish

ContentInformation
ProductBiosafety Cabinet – Class II- Type A1
Air balancing70% recirculation.30% exhaust
ProtectionProduct & personnel & environmental protection
Cleanliness levelISO class 5 as per ISO 14644-1
Average AirflowInflow Velocity Minimum 0.45 m/s ( 90 FPM) at 8” front opening
VelocityDown Velocity 0.30 m/s ( 65 FPM)
Noise level60 db on A scale
Light IntensityMinimum 900 lux inside the working area at ambient zero
MOCMain Body – Galvanized Iron with PU coated / Stainless Steel – Satin Finish Working Area – Stainless Steel IS 304 Grade Satin Finish
Supply FilterHEPA Filter having EU 13 rating with suitable size. .
Efficiency99.99% down to 0.3 Microns
Exhaust FilterHEPA Filter having EU 13 rating with suitable size.
Efficiency99.99% down to 0.3 Microns.
Pre Filter“Pureair” make, EU 4 rating with suitable size.
Efficiency90% down to 10 Microns.
Noise LevelLess than 70 db ‘A’.
Vibration Level InstrumentationMinimum.
Magnehelic Differential Pressure Gauge01 No. (make : Dwyer, USA) with each unit (To measure differential pressure across the supply HEPA filter).
Motor Blower AssemblyStatically & Dynamically balanced with suitable rating and size. (Induction motor with centrifugal blower) A Mounting unique spring suspension system to take care of vibration and noise.
3 Pins Switch & Socket15 AMPS – 1 set in each unit.
Other SwitchesOn/Off switches for motor blower & CFL lights.

2, Biosafety Cabinet – Class II Type B1

Pureair is the  best level ii biosafety cabinet manufacturer. Biosafety Cabinet Class II Type B1 has a common plenum from which 70% of air is exhausted, and 30% re-circulated to the work area as the down flow.

Type B1 cabinets also have a dedicated exhaust feature that eliminates re-circulation when work is performed towards the back within the interior of the cabinet. Toxic chemicals employed as an adjunct to microbiological processes should only be employed if they do not interfere with work when re-circulated in the down flow.

ContentInformation
ProductBio safety Cabinet – Class II Type B1
Air balancing30% recirculation, 70% exhaust
ProtectionProduct & Personnel & Environmental protection
Bio safety LevelBio safety Level 1 , 2 & 3
Exhaust Duct RequirementHard Duct Only
Control Plenum surrounded byNegative Plenum
Cleanliness levelISO class 5 as per ISO 14644-1
Average AirflowInflow Velocity – Minimum 0.45 m/s ( 90 FPM) at 8” front opening
VelocityDown Velocity – 0.30 m/s ( 65 FPM)
Noise level60 db on A scale
Light IntensityMinimum 900 lux inside the working area at ambient zero.
MOC Main Body –Galvanized Iron with PU coated / Stainless Steel – Satin Finish
Working Area –Stainless Steel IS 304 Grade Satin Finish
Supply FilterHEPA Filter having EU 13 rating with suitable size.
Efficiency99.99% down to 0.3 Microns.
Exhaust FilterHEPA Filter having EU 13 rating with suitable size.
Efficiency99.99% down to 0.3 Microns.
Pre FilterPureair” make, EU 4 rating with suitable size
Efficiency90% down to 10 Microns.
Noise LevelLess than 70 db ‘A’.
Vibration Level InstrumentationMinimum.
Differential Pressure GaugeMagnehelic Gauge – 01 No. (make : Dwyer, USA) with each unit (To measure differential pressure across the supply HEPA filter). Motor Blower Assembly Statically & Dynamically balanced with suitable rating and size.
Supply & Exhaust(Induction motor with centrifugal blower) A Mounting unique spring suspension system to take care of vibration and noise.
3 Pins Switch & Socket 15 AMPS – 1 set in each unit.
Other SwitchesOn/Off switches for motor blower & CFL lights
Microprocessor ControlAirflow display and UV Interlocking and Low airflow Alarm and Supply & Exhaust filter Fail

3, Biosafety Cabinet – Class II Type B2

Pureair” Biosafety Cabinet Class II Type B2 all inflow and down flow air is exhausted after HEPA filtration to the external environment without recirculation within the cabinet. Type B2 cabinets are suitable for work with toxic chemicals employed as an adjunct to microbiological processes under all circumstances since no re-circulation occurs. In theory, Type B2 cabinets may be considered to be the safest of all Class II biological safety cabinets since the total exhaust feature acts as a fail-safe in the event that the down flow and / or exhaust HEPA filtration systems cease to function normally. However, Class II Type B2 cabinets are, in practice, difficult to install, balance and maintain.

ContentInformation
ProductBio safety Cabinet – Class II Type B2
Air balancing0% recirculation.100% exhaust
ProtectionProduct & Personnel & Environmental protection
Bio safety LevelBio safety Level 1 , 2 & 3
Exhaust Duct RequirementHard Duct Only
Control Plenum surrounded byNegative Plenum
Cleanliness levelISO class 5 as per ISO 14644-1
Average AirflowInflow Velocity – Minimum 0.45 m/s ( 90 FPM) at 8” front opening
VelocityDown Velocity – 0.30 m/s ( 65 FPM)
Light IntensityMinimum 900 lux inside the working area at ambient zero
MOC Main Body –Galvanized Iron with PU coated / Stainless Steel – Satin Finish
Working Area –Stainless Steel IS 304 Grade Satin Finish
Supply FilterHEPA Filter having EU 13 rating with suitable size.
Efficiency99.99% down to 0.3 Microns.
Exhaust FilterHEPA Filter having EU 13 rating with suitable size.
Efficiency99.99% down to 0.3 Microns.
Pre Filter“Pureair” make, EU 4 rating with suitable size.
Efficiency90% down to 10 Microns.
Noise LevelLess than 70 db ‘A’.
Vibration Level InstrumentationMinimum.
Differential Pressure GaugeMagnehelic Gauge – 01 No. (make : Dwyer, USA) with each unit (To measure differential pressure across the supply HEPA filter).
Motor Blower AssemblyStatically & Dynamically balanced with suitable rating and size.
Supply & Exhaust(Induction motor with centrifugal blower) A Mounting unique spring suspension system to take care of vibration and noise.
3 Pins Switch & Socket15 AMPS – 1 set in each unit.
Other SwitchesOn/Off switches for motor blower & CFL lights.
Microprocessor ControlAirflow display and UV Interlocking and Low airflow Alarm and Supply & Exhaust filter Fail

4, Biosafety Cabinet – Class III

Pureair” Biosafety Cabinet Class III provides an absolute level of safety, which cannot be attained with Class I and Class II cabinets. All Class III cabinets are usually of welded metal construction and are designed to be gas tight.

Work is performed through glove ports in the front of the cabinet. During routine operation, negative pressure relative to the ambient environment is maintained within the cabinet. This provides an additional fail-safe mechanism in case physical containment is compromised. On all Class III cabinets, a supply of HEPA filtered air provides product protection and prevents cross contamination of samples. Exhaust air is usually HEPA filtered and incinerated.

Alternatively, double HEPA filtration with two filters in series may be utilized. Materials are transferred into the cabinet using a pass-through unit installed at the side of the work area. Class III cabinets usually exhaust air back to the laboratory; however, air may also be exhausted via a dedicated ductwork system to the external environment. When a dedicated ductwork system is employed, they are also suitable for work employing toxic chemicals as an adjunct to microbiological processes. All Class III biological safety cabinets are suitable for work with microbiological agents assigned to biosafety levels 1, 2, 3 and 4. They are frequently specified for work involving the most lethal biological hazards.

ContentInformation
Product PureairBio safety Cabinet Class III
Air balancing0% recirculation.100% exhaust
ProtectionProduct & Personnel & Environmental protection
Bio safety LevelBio safety Level 1 , 2 , 3 & 4
Exhaust Duct RequirementInside the room / Hard Duct Only
Control Plenum surrounded byNegative Plenum
Cleanliness levelISO class 5 as per ISO 14644-1
Negative PressurePressure differential between chamber and environment , Closed >0.5” WC
Front SashAirtight construction with Glove Port Arrangement
Noise level60 db on A scale
Light IntensityMinimum 900 lux inside the working area at ambient zero
MOC Main Body –Galvanized Iron with PU coated / Stainless Steel – Satin Finish
Working Area –Stainless Steel IS 304 Grade Satin Finish
Supply FilterHEPA Filter having EU 13 rating with suitable size.
Efficiency99.99% down to 0.3 Microns.
13 Exhaust Filter (Double Stage)HEPA Filter having EU 13 rating with suitable size.
Efficiency99.99% down to 0.3 Microns.
Pre FilterPureair” make, EU 4 rating with suitable size.
Efficiency90% down to 10 Microns.
Noise LevelLess than 70 db ‘A’.
Vibration Level InstrumentationMinimum.
Differential Pressure GaugeMagnehelic Gauge – 01 No. (make : Dwyer, USA) with each unit (To measure differential pressure across the supply HEPA filter).
Motor Blower AssemblyStatically & Dynamically balanced with suitable rating and size.
Supply & Exhaust(Induction motor with centrifugal blower) A Mounting unique spring suspension system to take care of vibration and noise.
3 Pins Switch & Socket15 AMPS – 1 set in each unit.
Other SwitchesOn/Off switches for motor blower & CFL lights.
Microprocessor ControlAirflow display and UV Interlocking and Low airflow Alarm and Supply & Exhaust filter Fail